Cyberwiz is now Cybreeze.

5 September 20266 min read

EN 303 645 next to EN 18031 — what overlaps, and which one the law asks for

Two consumer IoT security standards that cover much of the same ground, with one critical difference: only one of them is harmonised under the RED. When each is worth doing, and what carries across.

Rony Shulkin · Software Engineer

On this page
  1. What each one is
  2. Where they genuinely overlap
  3. Where they differ in a way that matters
  4. When each is worth doing
  5. The trap to avoid

If you are deciding between them, the answer is not a preference.

EN 18031 is the one the RED asks for. It is cited in the Official Journal for Articles 3(3)(d), (e) and (f), so applying it gives a presumption of conformity. ETSI EN 303 645 is not cited under the RED, so applying it — however thoroughly — gives you no presumption and leaves you demonstrating the essential requirements another way, which means a notified body.

That does not make EN 303 645 pointless. It is a better document to hand an engineering team, it is what several national schemes and procurement processes reference, and the work transfers. But it is not a route to a CE mark under the RED cybersecurity articles.

What each one is

ETSI EN 303 645EN 18031-1/-2/-3
Published byETSICEN/CENELEC
SubjectConsumer IoT, baseline securityRadio equipment, RED 3(3)(d), (e), (f)
Scope triggerConsumer IoT product, by categoryRadio equipment, by the RED scope tests
Cited in the OJ under REDNoYes, with restrictions, by Decision (EU) 2025/138
Presumption of conformityNone under the REDYes, where no restriction bites
Conformance assessment specETSI TS 103 701The standard's own decision trees
StructureProvisions grouped under thirteen headingsMechanisms, asset-driven, decision trees
Mandatory vs recommendedMixed — both, explicitly markedRequirement outcomes: met, not met, not applicable

EN 303 645's thirteen headings are the ones most engineers have seen quoted: no universal default passwords, a means to manage vulnerability reports, keep software updated, securely store sensitive parameters, communicate securely, minimise exposed attack surfaces, ensure software integrity, protect personal data, make systems resilient to outages, examine telemetry, make it easy to delete user data, make installation and maintenance easy, validate input data.

Counts vary by version and by what you are counting. V3.1.3 has considerably more individual provisions than thirteen, with a subset marked mandatory and the rest recommended, and ETSI TS 103 701 V2.1.1 is the matching conformance assessment method. Check the version you hold rather than a number from a blog post, this one included.

Where they genuinely overlap

Both documents are descended from the same body of consumer IoT security thinking, so the substance converges on the things that actually matter in a connected device.

Strong overlap, and the work transfers directly:

  • No universal default credentials. EN 303 645's first provision, and the subject of the EN 18031 access control and authentication mechanisms. This is also where the password restriction in the citing decision bites, so the overlap is in the most consequential place.
  • Secure update. Both require a mechanism, both care about authenticity and integrity, and both want the update path documented rather than assumed.
  • Secure storage of sensitive parameters. Keys, credentials, provisioning material.
  • Secure communication. Transport protection, and the question of what the device does when it cannot establish it.
  • Minimise attack surface. Open ports, debug interfaces, unused services.
  • Vulnerability disclosure. EN 303 645 requires a means to manage reports. The RED does not — but the CRA does, explicitly and as a running process.
  • Deletion of user data and personal data protection, which map onto EN 18031-2.

So a product that has done EN 303 645 properly has done much of the engineering that EN 18031 asks about. What it has not done is the EN 18031 assessment, which is a different artefact with a different structure.

Where they differ in a way that matters

The assessment method is not interchangeable. EN 303 645 is provision-based: you go through the list and record conformance per provision, with TS 103 701 giving the test method. EN 18031 is asset-driven: you enumerate assets, that determines which mechanisms are in scope, and each is assessed through a decision tree — see how EN 18031 is actually assessed.

The consequence is that you cannot transcribe one into the other. The evidence transfers; the reasoning does not. An EN 303 645 conformance record is not an EN 18031 assessment with different headings, because EN 18031 asks a question EN 303 645 never asks — which of these mechanisms does this product's asset inventory require.

The scope triggers are different shapes. EN 303 645 is about consumer IoT as a product category. EN 18031 follows the RED's scope tests, which turn on connectivity, personal data, toys, childcare, wearables and value transfer. A product can be plainly consumer IoT and in scope for only one part of EN 18031; a product can be industrial and still in scope for 3(3)(d).

Recommended is not optional in the same way. EN 303 645 marks provisions as mandatory or recommended, and a conformance claim can be made against the mandatory set. EN 18031's outcomes are met, not met or not applicable, and "not applicable" is a claim about the product that you have to support. There is no "recommended, not implemented" cell.

When each is worth doing

Do EN 18031 if you are placing radio equipment on the EU market and want to self-assess. There is no alternative route to the presumption of conformity for 3(3)(d), (e) and (f).

Do EN 303 645 when one of these is true:

  • A customer, retailer or public procurement process asks for it by name. This happens often, and it is the most common reason it is on a roadmap.
  • You are selling into a national scheme that references it.
  • You want a document your engineers can work from directly. This is a real advantage. EN 303 645 reads like a security specification. EN 18031 reads like an assessment framework, which is what it is, and it is harder to hand to a firmware team as a to-do list.
  • You are building toward the CRA and want a structured baseline to work against while the harmonised standards are still in development.

That last one is worth expanding. The CRA's Annex I Part I requirements are broader than EN 303 645 but they are not in tension with it, and there is no cited harmonised standard for the CRA yet. A team that implements EN 303 645's mandatory provisions is doing work that will count, even though the compliance route is not settled.

Do both if you are a consumer device maker selling into the EU and the UK, or into procurement. The marginal cost of the second is far below the first, for the same reason that a second compliance framework is mostly re-filing: the evidence is shared and only the reasoning is duplicated.

The trap to avoid

The specific mistake I would warn about: do not let an EN 303 645 conformance report be the cybersecurity content of your RED technical file.

It is a credible document and it describes real work, which is exactly why it gets filed. But Annex V of the RED asks for the harmonised standards applied in full or in part, and where not applied, a description of the solutions adopted to meet the essential requirements. An EN 303 645 report is neither — it is conformance with a different standard. A file built that way looks substantial and answers a question nobody asked.

If you have an EN 303 645 report and need a RED file, the report goes in as evidence, cited from the EN 18031 assessment rows it supports. That is a genuinely useful place for it. See what goes in the RED cybersecurity technical file.

Primary sources: Commission Implementing Decision (EU) 2025/138 for what is cited under the RED and with what restrictions, and the Official Journal's harmonised standards listings for the RED, which is the only authoritative answer to "is this standard harmonised". ETSI's own standards are freely downloadable from the ETSI portal, which EN 18031 is not.

Filed underProduct security