When RED cybersecurity needs a notified body — and when it does not
The rule is one sentence in Article 17: apply the harmonised standards in full and you can self-assess; fall short in any way and a notified body becomes mandatory. The hard part is knowing what "in full" means.
Michael Parkadze · Software Engineer

On this page
The test is simple to state and expensive to get wrong.
Apply the relevant harmonised standards in full, and you can self-assess under Annex II of the RED — internal production control, no third party. Fall short in any way — not applied, partly applied, no standard exists, or a restriction removes the presumption for a conclusion you relied on — and Annex III or Annex IV applies, both of which involve a notified body.
There is no middle route, and the decision is not discretionary. Article 17(4) of Directive 2014/53/EU is the operative provision.
The three routes
| Route | Name | Notified body | When |
|---|---|---|---|
| Annex II | Internal production control | No | Harmonised standards applied in full |
| Annex III | EU type examination + conformity to type | Yes | Standards not applied in full, or do not exist |
| Annex IV | Full quality assurance | Yes | As above, where you prefer a system-level approval |
Annex III assesses a type. Annex IV approves your quality system and is usually only worth it at volume across a product family. For a single product family, Annex III is the normal answer.
The choice between III and IV is yours. The choice between II and the other two is not.
The four ways you lose Annex II on cybersecurity
This is the useful part, because "applied in full" is where the real decision sits.
1. You did not apply the standard
Obvious, and it does happen — a team that implemented ETSI EN 303 645 instead, for example. EN 303 645 is not cited in the Official Journal under the RED, so it does not give a presumption of conformity for 3(3)(d), (e) or (f). See EN 303 645 next to EN 18031 for why that is a trap rather than an equivalence.
2. You applied it in part
You met most of a part of EN 18031 and solved two or three requirements your own way. That is permitted — Annex V explicitly contemplates standards applied in part, and asks you to describe the solutions adopted. What it is not is a route to self-assessment. Partial application means Annex III or IV.
Worth being honest with yourself here. "We applied EN 18031-1 in full except for the logging requirement, where our approach is different" is partial application. It does not become full application because the deviation is small or well-reasoned.
3. A restriction removes the presumption for a conclusion you relied on
This is the one specific to cybersecurity and it is the one most often missed.
Commission Implementing Decision (EU) 2025/138 cited EN 18031-1, -2 and -3 with restrictions. Where a restriction applies to your design, the standard confers no presumption of conformity for that requirement — so in substance you are in the "not applied in full" position for it, and the notified body requirement follows.
The restrictions worth checking against your design, covered in detail in the restrictions post:
- Any path through setup that leaves the product in service with no password set, under clauses 6.2.5.1 and 6.2.5.2. All three parts.
- Parental or guardian access control not ensured, for equipment in the relevant Part 2 clauses. Toys, childcare, children's wearables.
- The assessment criteria in clause 6.3.2.4 of Part 3.
- Any justification that rests on a "rationale" or "guidance" section. This one is usually fixable by rewriting the assessment rather than changing the product.
4. No harmonised standard covers the requirement
Not currently an issue for RED cybersecurity — all three essential requirements have a cited standard. It is very much an issue for the CRA, where nothing has been cited in the Official Journal yet, which is why the CRA conformity routes work differently. See the CRA conformity assessment routes.
What the notified body route costs
The money matters less than the calendar.
A notified body under Annex III issues an EU type examination certificate, which means reviewing your technical documentation, examining the type and testing against the essential requirements. For a cybersecurity assessment that is a document review plus testing, and the document review is where schedules slip — not because the body is slow, but because the file that goes in is usually not ready.
What actually causes delay, in order:
- "Not applicable" rows with no supporting basis. Every one of them comes back as a question. If your asset inventory is thin, this is a round trip per mechanism. How EN 18031 is assessed covers what a defensible one looks like.
- Evidence referenced but not supplied, or supplied without the firmware version it describes.
- A scoping decision that is asserted rather than reasoned. If the file says 3(3)(f) does not apply and does not say why, that is the first question.
- Design changes discovered during review. The password-skip path is the classic: found in the recovery flow, fixed in firmware, which means a new build, which means re-testing.
So the practical advice is uncomfortable but accurate: the way to shorten the notified body route is to prepare the file as if you were self-assessing, and then hand it over. Teams that treat the notified body as the thing that will tell them what to produce spend longer and pay more.
A decision you can make in an afternoon
Before any of this, three questions answer the route for most products:
- Which parts of EN 18031 are in scope? The scope tests in Delegated Regulation (EU) 2022/30, Articles 1 and 2.
- Is there any path through setup, recovery or local fallback that leaves the product running with no credential? Including after a factory reset. If yes, and you are not changing it, you need a notified body.
- Is the product a toy, childcare equipment or a children's wearable? If yes, the Part 2 parental control restriction is directly in your path and worth reading before anything else.
Question 2 is the one to put in front of a firmware engineer rather than a compliance manager, and it is worth asking as a code question — grep the provisioning state machine for the states that reach "provisioned" — rather than as a documentation question. The documented flow and the implemented flow diverge in exactly this spot.
One thing that is not a factor
Whether your product is "high risk" does not enter into it. The RED's cybersecurity conformity route is decided purely by whether you applied the harmonised standards in full. There is no product class, no risk tier, no equivalent of the CRA's Annex III.
This changes under the CRA, which introduces product classes that drive the route independently of which standards you applied — a product in Annex III class II needs a notified body even with harmonised standards fully applied, once such standards exist. That is a genuine structural difference between the two regimes, and worth knowing before you build a process around the RED logic. The dual regime post has the handover dates.
Primary sources: Directive 2014/53/EU Article 17 and Annexes II, III and IV, and Implementing Decision (EU) 2025/138 for the restrictions. The Commission's RED guide is useful background on the conformity modules, though it predates the cybersecurity articles becoming applicable.